Short Specs
Perfect Fit ™ Solvent Weld DWV (D Series)
STI™ Gasketed Sewer SDR 35 (G Series)
Ultra Heavy Duty™ Gasketed Sewer SDR 14 (U Series)
Heavy Wall Gasketed Sewer SDR 26 (H Series)
Solvent Weld Sewer SDR 35 (P Series)
Perfect Fit™ Solvent Weld Drain, Waste, and Vent (DWV) Fittings (4”-12”) (D Series)
4” through 12” injection molded solvent weld Drain, Waste, and Vent (DWV) fittings shall be manufactured in accordance with ASTM D2665, F1866, F2135, and CSA B181.2, as applicable. Solvent weld DWV fittings shall be certified by the National Sanitation Foundation (NSF) to meet ASTM D2665, F1866, and ASTM F2135, as applicable; and by the Canadian Standards Association (CSA) to meet CSA B181.2 as applicable. They shall be certified by the International Association of Plumbing and Municipal Offi cials (IAPMO) to meet the requirements of the Uniform Plumbing Code (UPC), as applicable.
STI™ Gasketed Sewer Fittings SDR 35 (4”-12”) (G Series)
4” through 12” injection molded gasketed SDR 35 sewer fittings shall be manufactured in accordance with ASTM D 3034, ASTM F1336, and CSA B182.2. They shall be injection molded from virgin PVC compound having a cell classification of 12454 or 13343 in accordance with, and certified by the National Sanitation Foundation (NSF), to meet ASTM D 1784. Gaskets shall be manufactured in accordance with ASTM F 477 or ASTM F 913. Gaskets shall be firmly seated in fitting in order to ensure proper installation and to prevent dislocation or misalignment during system assembly. Gasket joints must comply with ASTM D 3212 Internal Pressure Test (exfiltration) and Vacuum Test (infiltration) at 5 degrees of gasket joint deflection.
Where available, reducing branches on injection molded 8”, 10”, and 12” tees, wyes, and tee-wyes shall be minimum DR18 wall thickness in the reducing branch body and reducing branch hub below the gasket race.
Gasketed SDR 35 sewer fittings shall be certified by the National Sanitation Foundation (NSF) and, in applicable configurations, by the International Association Of Plumbing And Municipal Officials (IAPMO) to meet ASTM D 3034, and by the Canadian Standards Association (CSA) to meet CSA B182.2.
Ultra Heavy Duty™ Gasketed Sewer Fittings SDR 14 (4"-8") (U Series)
Gasketed Ultra Heavy Duty™ sewer fittings shall be manufactured to accept ASTM D 3034 SDR 35 or SDR 26 sewer pipe. Fitting bodies shall have a minimum of SDR 14 wall thickness. Fitting hubs below the gasket race shall have a minimum wall thickness of SDR 18. Fitting gaskets shall comply with ASTM F 477 or F 913. Fitting gaskets shall be locked firmly in position to prevent displacement. Fittings shall be injection molded from virgin PVC compound having a minimum cell classification of 12454 or 13343 in accordance with, and certified by the National Sanitation Foundation (NSF), to meet ASTM D 1784. Gasket joints must comply with ASTM D 3212 Internal Pressure Test (exfiltration) and Vacuum Test (infiltration) at 5 degrees of gasket joint deflection. Gasketed Ultra Heavy Duty™ sewer fittings shall be certified by the National Sanitation Foundation (NSF) to meet ASTM D 3034. Ultra Heavy Duty™ sewer fittings shall be Plastic Trends or equivalent.
Heavy Wall Gasketed Sewer Fittings SDR 26 (4”- 18”) (H Series)
4" through 18" gasketed SDR 26 sewer fittings shall be manufactured in accordance with ASTM D 3034 and F 1336. Fitting gaskets shall comply with ASTM F 477 or ASTM F 913. Fitting gaskets shall be locked firmly in position to prevent displacement. 4" through 8" SDR 26 fittings shall have green color coded gasket retaining rings for easy identification. 4" through 8" fittings shall be injection molded from virgin PVC compound having a minimum cell classification of 12454 or 13343 in accordance with, and certified by the National Sanitation Foundation (NSF), to meet ASTM D 1784. 10" through 15" gasketed SDR 26 sewer fittings may be injection molded or fabricated from pipe meeting the requirements of ASTM D 3034. Gasket joints of all fitting sizes must comply with ASTM D 3212 Internal Pressure Test (exfiltration) and Vacuum Test (infiltration) at 5 degrees of gasket joint deflection. Gasketed SDR 26 sewer fittings shall be certified by the National Sanitation Foundation (NSF) to meet ASTM D 3034.
Solvent Weld Sewer Fittings SDR 35 (4”-12”) (P Series)
4” through 12” injection molded solvent weld SDR 35 sewer fittings shall be manufactured in accordance with ASTM D 3034 and CSA B182.2. They shall be molded from virgin PVC compound having a minimum cell classification of 12454-B in accordance with, and certified by the National Sanitation Foundation (NSF), to meet ASTM D 1784. Solvent weld SDR 35 sewer fittings shall be certified by the National Sanitation Foundation (NSF) to meet ASTM D 3034, and, in applicable confi gurations, by the Canadian Standards Association (CSA) to meet CSA B182.2.
CIOD Pressure Fittings Specification (C Series)
Fabricated fittings 10” and greater shall conform
to the requirements of AWWA C900 and C905
and CSA B137.3.
Fabricated fittings shall have a dimensional ratio
equal to that of the pipe they are being installed
on.
All PVC CIOD fittings shall incorporate integral elastomeric gasket bell joints. Materials used in the manufacture of PVC fittings shall equal or exceed cell class 12454 (ASTM 1784) with a hydrostatic design basis of 27.58 Mpa at 23°C as outlined in AWWA C900 and C905, and CSA B137.3. The compound shall be listed with National Sanitation Foundation Fabricated fittings shall be manufactured from segments of PVC pipe bonded together and over wrapped with fiberglass-reinforced polyester to the requirements of AWWA C900 and C905, and CSA B137.3. All bends, up to and including 45°, shall be constructed from a single section of PVC pipe, without joints, bonding or fiberglassreinforced polyester wrapping.
Note: Since the bends 45° or less are one piece, fibreglassing is redundant and can be eliminated. The pressure rating of the fittings shall be equal to the pressure rating of the pipe they are being installed on. The manufacturer shall meet all the qualification test requirements as outlined in CSA B137.3 All fittings shall be marked with the following identifications:
- Nominal size, CIOD
- Manufacturers name or trademark
- AWWA pressure rating/pressure class and standard number to which the fitting is made
- Indication of potable water use, potable, P, PW
- CSA Standard number
- Proper handling label